Alt Model #
Fusion CUPS Series 3.5 KVA / 48 V : Fusion Series Pure Sine Wave Commercial UPS
Fusion CUPS 3.2 KVA / 36 V : Pure Sine Wave Commercial UPS
Fusion CUPS Series 2.5 KVA / 48 V : Fusion Series Pure Sine Wave Commercial UPS
Series #
Fusion CUPS Series 3.5 KVA / 48 V : Fusion Series
Fusion CUPS 3.2 KVA / 36 V : Fusion Series
Fusion CUPS Series 2.5 KVA / 48 V : Fusion Series
Fusion CUPS Series 3.5 KVA / 48 V
Fusion CUPS Series 2.5 KVA / 48 V
Fusion CUPS Series 3.5 KVA / 48 V
Fusion CUPS Series 2.5 KVA / 48 V
Buy Now Fusion CUPS Series 3.5 KVA / 48 V
Home Shop 18 ₹ 20093 33% off
Sukam ₹ 29990
Refreshed 3 days ago
Buy Now Fusion CUPS Series 2.5 KVA / 48 V
SnapDeal ₹ 13991 48% off
Amazon.in
Sukam ₹ 26900
Refreshed 1 week ago
Highlights
Capacity
Fusion CUPS Series 3.5 KVA / 48 V : 3500 VA
Fusion CUPS 3.2 KVA / 36 V : 3200 VA
Fusion CUPS Series 2.5 KVA / 48 V : 2500 VA
Warranty(Months)
Fusion CUPS Series 3.5 KVA / 48 V : 
Fusion CUPS 3.2 KVA / 36 V : 24
Fusion CUPS Series 2.5 KVA / 48 V : 
General Specification
Technology
Fusion CUPS Series 3.5 KVA / 48 V : Micro Controller Based PWM Technology using MOSFETs.
Fusion CUPS 3.2 KVA / 36 V : Micro Controller Based PWM Technology using MOSFETs.
Fusion CUPS Series 2.5 KVA / 48 V : Micro Controller Based PWM Technology using MOSFETs.
UPS Overload / UPS Short Circuit
Fusion CUPS Series 3.5 KVA / 48 V : -
Fusion CUPS 3.2 KVA / 36 V : Above 100%
Fusion CUPS Series 2.5 KVA / 48 V : -
Charger Current
Fusion CUPS Series 3.5 KVA / 48 V : 13A+_1.0 A or 16A+_1.0A
Fusion CUPS 3.2 KVA / 36 V : 13+_2.0 AMP
Fusion CUPS Series 2.5 KVA / 48 V : 13A+_1.0 A or 16A+_1.0A
Shot Circuit Protection
Fusion CUPS Series 3.5 KVA / 48 V : -
Fusion CUPS 3.2 KVA / 36 V : >300% load(few msec)
Fusion CUPS Series 2.5 KVA / 48 V : -
Capacity Battery
Fusion CUPS Series 3.5 KVA / 48 V : 48 V
Fusion CUPS 3.2 KVA / 36 V : 36 V
Fusion CUPS Series 2.5 KVA / 48 V : 48 V
Battery Features
Battery
Fusion CUPS Series 3.5 KVA / 48 V : Hups
Fusion CUPS 3.2 KVA / 36 V : Hups
Fusion CUPS Series 2.5 KVA / 48 V : Hups
Efficiency (on battery mode)
Fusion CUPS Series 3.5 KVA / 48 V : >88%
Fusion CUPS 3.2 KVA / 36 V : >88%
Fusion CUPS Series 2.5 KVA / 48 V : >88%
Low Battery Cutout
Fusion CUPS Series 3.5 KVA / 48 V : 10.5V+_0.2V
Fusion CUPS 3.2 KVA / 36 V : 10.5V+_0.2V
Fusion CUPS Series 2.5 KVA / 48 V : 10.5V+_0.2V
Recommended Battery
Fusion CUPS Series 3.5 KVA / 48 V : 12V(SMF/Flooded)
Fusion CUPS 3.2 KVA / 36 V : 100-200 Ah
Fusion CUPS Series 2.5 KVA / 48 V : 12V(SMF/Flooded)
Max. Battery Boost Level
Fusion CUPS Series 3.5 KVA / 48 V : 14.3V ± 0.2V
Fusion CUPS 3.2 KVA / 36 V : 14.4V ± 0.2V
Fusion CUPS Series 2.5 KVA / 48 V : 14.3V ± 0.2V
Max. Battery Float Level
Fusion CUPS Series 3.5 KVA / 48 V : 13.7V ± 0.2V
Fusion CUPS 3.2 KVA / 36 V : 13.7V ± 0.2V
Fusion CUPS Series 2.5 KVA / 48 V : 13.7V ± 0.2V
Battery Recharge Time
Fusion CUPS Series 3.5 KVA / 48 V : FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V
Fusion CUPS 3.2 KVA / 36 V : FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V
Fusion CUPS Series 2.5 KVA / 48 V : FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V
Design
Fusion CUPS Series 3.5 KVA / 48 V : 
Fusion CUPS 3.2 KVA / 36 V : -
Fusion CUPS Series 2.5 KVA / 48 V : -
DSP is one of the most powerful and advanced technologies which is used for high speed processing applications. This helps in saving loss of power, which happens during the process of power generation by a normal Commercial UPS.
Fusion CUPS Series 3.5 KVA / 48 V : Pure Sinewave Output
Fusion CUPS 3.2 KVA / 36 V : -
Fusion CUPS Series 2.5 KVA / 48 V : -
Pure Sine Wave is the purest and is 100% clean, regulated, and completely stable and distortion free power output, which is absolutely safe for running complex appliances without humming & irritating sound.
Fusion CUPS Series 3.5 KVA / 48 V : 
Fusion CUPS 3.2 KVA / 36 V : -
Fusion CUPS Series 2.5 KVA / 48 V : -
In case of power failure, the process of switching over the battery mode is of few milliseconds hence the power supplied to the connected appliances, like computer is not interrupted, as a result of which the system does not reboot.
Fusion CUPS Series 3.5 KVA / 48 V : 
Fusion CUPS 3.2 KVA / 36 V : -
Fusion CUPS Series 2.5 KVA / 48 V : -
A feature, which will automatically switch on to the Battery mode in case there is extreme high or low voltage supplied from the mains, which protects your valuable equipment.
Fusion CUPS Series 3.5 KVA / 48 V : 
Fusion CUPS 3.2 KVA / 36 V : -
Fusion CUPS Series 2.5 KVA / 48 V : -
During power failure, the voltage supplied by CUPS will not differ with the increase or decrease in the load, hence delivering electricity consistently through CUPS. The voltage & frequency at the battery mode will be consistent and will not be affected by increase or decrease in the load.
Input & Output
Output Voltage on Mains Mode
Fusion CUPS Series 3.5 KVA / 48 V : 220V ± 10V
Fusion CUPS 3.2 KVA / 36 V : 180V -245 V
Fusion CUPS Series 2.5 KVA / 48 V : 220V ± 10V
Output frequency on UPS Mode
Fusion CUPS Series 3.5 KVA / 48 V : 50.0 Hz +_ 0.3 Hz
Fusion CUPS 3.2 KVA / 36 V : 50.0 Hz +_ 0.1 Hz
Fusion CUPS Series 2.5 KVA / 48 V : 50.0 Hz +_ 0.3 Hz
Input Frequency
Fusion CUPS Series 3.5 KVA / 48 V : -
Fusion CUPS 3.2 KVA / 36 V : 45~55 Hz
Fusion CUPS Series 2.5 KVA / 48 V : -
Voltage Range NW UPS Mode
Main AC Low Cut
Fusion CUPS Series 3.5 KVA / 48 V : 140+_10V
Fusion CUPS 3.2 KVA / 36 V : 185+_10V
Fusion CUPS Series 2.5 KVA / 48 V : 140+_10V
Main AC Low Cut Recovery
Fusion CUPS Series 3.5 KVA / 48 V : 150+_10V
Fusion CUPS 3.2 KVA / 36 V : 190+_10V
Fusion CUPS Series 2.5 KVA / 48 V : 150+_10V
Main AC High Cut
Fusion CUPS Series 3.5 KVA / 48 V : 270+_10V
Fusion CUPS 3.2 KVA / 36 V : 265+_10V
Fusion CUPS Series 2.5 KVA / 48 V : 270+_10V
Main AC High Cut Recovery
Fusion CUPS Series 3.5 KVA / 48 V : 260+_10V
Fusion CUPS 3.2 KVA / 36 V : 260+_10V
Fusion CUPS Series 2.5 KVA / 48 V : 260+_10V
Fusion CUPS Series 3.5 KVA / 48 V : 140V-260V+_10V
Fusion CUPS 3.2 KVA / 36 V : 115V-285V+_10V
Fusion CUPS Series 2.5 KVA / 48 V : 140V-260V+_10V
Voltage Range NW UPS Mode - Narrow-Wide range is the range of input voltage for which power inverter will work on line mode (external power) and then switch to backup mode. For example, you have got a power inverter that has got ‘narrow range’ of 170 V to 250 V, it won’t switch over to batteries backup if voltage is higher than 170 V and lower than 250 V. On the other hands, if ‘wide range’ is selected which is supposedly designed for 110 V to 260 V, the power inverter will not switch to backup mode as long as external power is available and voltage is higher than 110 V and lower than 260 V.
Voltage Range WW UPS Mode
Main AC High Cut
Fusion CUPS Series 3.5 KVA / 48 V : 260 ±10V
Fusion CUPS 3.2 KVA / 36 V : 285 ± 10V
Fusion CUPS Series 2.5 KVA / 48 V : 260 ±10V
Main AC High Cut Recovery
Fusion CUPS Series 3.5 KVA / 48 V : 250 ± 10V
Fusion CUPS 3.2 KVA / 36 V : 275 ± 10V
Fusion CUPS Series 2.5 KVA / 48 V : 250 ± 10V
Main AC Low Cut
Fusion CUPS Series 3.5 KVA / 48 V : 190 ± 10V
Fusion CUPS 3.2 KVA / 36 V : 105 ± 10V
Fusion CUPS Series 2.5 KVA / 48 V : 190 ± 10V
Main AC Low Cut Recovery
Fusion CUPS Series 3.5 KVA / 48 V : 180 ± 10V
Fusion CUPS 3.2 KVA / 36 V : 120 ± 10V
Fusion CUPS Series 2.5 KVA / 48 V : 180 ± 10V
Voltage Range WW UPS Mode
Fusion CUPS Series 3.5 KVA / 48 V : 180 -260 ±10 V
Fusion CUPS 3.2 KVA / 36 V : 105-285 ±10 V
Fusion CUPS Series 2.5 KVA / 48 V : 180 -260 ±10 V
Dimensions
Weight
Fusion CUPS Series 3.5 KVA / 48 V : 30.5 kg
Fusion CUPS 3.2 KVA / 36 V : 20.1 kg
Fusion CUPS Series 2.5 KVA / 48 V : 25.1 kg
Width
Fusion CUPS Series 3.5 KVA / 48 V : 395 mm
Fusion CUPS 3.2 KVA / 36 V : 295 mm
Fusion CUPS Series 2.5 KVA / 48 V : 395 mm
Length
Fusion CUPS Series 3.5 KVA / 48 V : 245 mm
Fusion CUPS 3.2 KVA / 36 V : 245 mm
Fusion CUPS Series 2.5 KVA / 48 V : 245 mm
Height
Fusion CUPS Series 3.5 KVA / 48 V : 355 mm
Fusion CUPS 3.2 KVA / 36 V : 255 mm
Fusion CUPS Series 2.5 KVA / 48 V : 355 mm