Alt Model #
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : Supermax - Series - II
NM36MX1KK11 1KVA/800W : Max Series
NM72MX2KK11 2KVA / 1600W : Max Series
NM72MX3KK11 3KVA / 2400W : Max Series
Supermax I 5KVA to 30KVA : Supermax - Series-I
Series #
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : Online UPS
NM36MX1KK11 1KVA/800W : Online UPS
NM72MX2KK11 2KVA / 1600W : Online UPS
NM72MX3KK11 3KVA / 2400W : Online UPS
Supermax I 5KVA to 30KVA : Online UPS
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA
NM36MX1KK11 1KVA/800W
NM72MX2KK11 2KVA / 1600W
NM72MX3KK11 3KVA / 2400W
NM36MX1KK11 1KVA/800W
NM72MX2KK11 2KVA / 1600W
NM72MX3KK11 3KVA / 2400W
Buy Now NM72MX3KK11 3KVA / 2400W
SnapDeal ₹ 24913 3% off
Microtek ₹ 25800
Refreshed 4 days ago
Highlights
Capacity
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 30000 VA
NM36MX1KK11 1KVA/800W : 1000 VA
NM72MX2KK11 2KVA / 1600W : 2000 VA
NM72MX3KK11 3KVA / 2400W : 3000 VA
Supermax I 5KVA to 30KVA : 30000 VA
Warranty(Months)
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 24
NM36MX1KK11 1KVA/800W : 24
NM72MX2KK11 2KVA / 1600W : 24
NM72MX3KK11 3KVA / 2400W : 24
Supermax I 5KVA to 30KVA : 24
General Specification
Technology
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : Double Conversion high Freq. Switching PWM, using IGBT's
NM36MX1KK11 1KVA/800W : Advanced PFC Technology
NM72MX2KK11 2KVA / 1600W : Advanced PFC Technology
NM72MX3KK11 3KVA / 2400W : Advanced PFC Technology
Supermax I 5KVA to 30KVA : Double Conversion high Freq. Switching PWM, using IGBT's
UPS Transfer Time
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : -
NM36MX1KK11 1KVA/800W : 4 msec (Typical 2.5 msec)
NM72MX2KK11 2KVA / 1600W : 4 msec (Typical 2.5 msec)
NM72MX3KK11 3KVA / 2400W : 4 msec (Typical 2.5 msec)
Supermax I 5KVA to 30KVA : -
UPS Overload / UPS Short Circuit
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 125% for 2minuted / 150% for 30S
NM36MX1KK11 1KVA/800W : >110% 30s turn to bypass mode; >150%, 200ms turn to bypass
NM72MX2KK11 2KVA / 1600W : >110% 30s turn to bypass mode; >150%, 200ms turn to bypass
NM72MX3KK11 3KVA / 2400W : >110% 30s turn to bypass mode; >150%, 200ms turn to bypass
Supermax I 5KVA to 30KVA : 125% for 2minuted / 150% for 30S
Efficiency
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : > 80%
NM36MX1KK11 1KVA/800W : -
NM72MX2KK11 2KVA / 1600W : -
NM72MX3KK11 3KVA / 2400W : -
Supermax I 5KVA to 30KVA : > 80%
Charger Current
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : -
NM36MX1KK11 1KVA/800W : 0.7A ~ 08A
NM72MX2KK11 2KVA / 1600W : 0.7A ~ 08A
NM72MX3KK11 3KVA / 2400W : 0.7A ~ 08A
Supermax I 5KVA to 30KVA : -
Communication Interface
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : -
NM36MX1KK11 1KVA/800W : RS232; SNMP (optional)
NM72MX2KK11 2KVA / 1600W : RS232; SNMP (optional)
NM72MX3KK11 3KVA / 2400W : RS232; SNMP (optional)
Supermax I 5KVA to 30KVA : -
Shot Circuit Protection
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : Instant
NM36MX1KK11 1KVA/800W : 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode), 5 cycles turn off inverter, provide alarm (battery mode), input fuse blown or breaker action
NM72MX2KK11 2KVA / 1600W : 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode), 5 cycles turn off inverter, provide alarm (battery mode), input fuse blown or breaker action
NM72MX3KK11 3KVA / 2400W : 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode), 5 cycles turn off inverter, provide alarm (battery mode), input fuse blown or breaker action
Supermax I 5KVA to 30KVA : Instant
Crest Factor
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 3:1 (max)
NM36MX1KK11 1KVA/800W : 3:1 (max)
NM72MX2KK11 2KVA / 1600W : 3:1 (max)
NM72MX3KK11 3KVA / 2400W : 3:1 (max)
Supermax I 5KVA to 30KVA : 3:1 (max)
THD (Non-Liner Load)
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : <5%
NM36MX1KK11 1KVA/800W : <5%
NM72MX2KK11 2KVA / 1600W : <5%
NM72MX3KK11 3KVA / 2400W : <5%
Supermax I 5KVA to 30KVA : <5%
THD (Liner Load)
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : <3%
NM36MX1KK11 1KVA/800W : <3%
NM72MX2KK11 2KVA / 1600W : <3%
NM72MX3KK11 3KVA / 2400W : <3%
Supermax I 5KVA to 30KVA : <3%
Applications
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : Networking Equipment, Computer Rooms, Mission Critical Process, Bank, Office, Railways, Hospitals, Defence and Telecom Centers, all types of Single Ph. Loads
NM36MX1KK11 1KVA/800W : Small Computer Network, Servers Cyber Café, Banks And Offices.
NM72MX2KK11 2KVA / 1600W : Small Computer Network, Servers Cyber Café, Banks And Offices.
NM72MX3KK11 3KVA / 2400W : Small Computer Network, Servers Cyber Café, Banks And Offices.
Supermax I 5KVA to 30KVA : Networking Equipment, Computer Rooms, Mission Critical Process, Bank, Office, Railways, Hospitals, Defence and Telecom Centers, all types of Single Ph. Loads
Battery Features
Battery
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : RS232
NM36MX1KK11 1KVA/800W : RS232
NM72MX2KK11 2KVA / 1600W : RS232
NM72MX3KK11 3KVA / 2400W : RS232
Supermax I 5KVA to 30KVA : RS232
Input DC Range
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 180 / 360 VDC
NM36MX1KK11 1KVA/800W : 36V DC
NM72MX2KK11 2KVA / 1600W : 72VDC
NM72MX3KK11 3KVA / 2400W : 72VDC
Supermax I 5KVA to 30KVA : 180 / 360 VDC
Efficiency (on battery mode)
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : ≥ 90% on rated full load
NM36MX1KK11 1KVA/800W : ≥ 85%~92%
NM72MX2KK11 2KVA / 1600W : ≥ 85%~92%
NM72MX3KK11 3KVA / 2400W : ≥ 85%~92%
Supermax I 5KVA to 30KVA : ≥ 90% on rated full load
Input & Output
Input Voltage
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 360V AC~450V AC ± 5V AC, Three
NM36MX1KK11 1KVA/800W : When load < 50%, range is 118±5VAC~295±5VAC When ± 50% load, input range is 160±5VAC~295±5VAC
NM72MX2KK11 2KVA / 1600W : When load < 50%, range is 118±5VAC~295±5VAC When ± 50% load, input range is 160±5VAC~295±5VAC
NM72MX3KK11 3KVA / 2400W : When load < 50%, range is 118±5VAC~295±5VAC When ± 50% load, input range is 160±5VAC~295±5VAC
Supermax I 5KVA to 30KVA : 160V AC~270V AC ±5V AC, Single Phase for upto 10KVA and 360V AC~450V AC ±5V AC, Three Phase for upto 30KVA
Output Voltage on UPS Mode
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 400V AC Phase to Phase ± 3% on 100% unbalance load
NM36MX1KK11 1KVA/800W : 200V~230V ± 10%
NM72MX2KK11 2KVA / 1600W : 200V~230V ± 10%
NM72MX3KK11 3KVA / 2400W : 200V~230V ± 10%
Supermax I 5KVA to 30KVA : 230V Ac ±1%
Output frequency on UPS Mode
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 50Hz ± 0.5%
NM36MX1KK11 1KVA/800W : 50Hz ± 0.2%
NM72MX2KK11 2KVA / 1600W : 50Hz ± 0.2%
NM72MX3KK11 3KVA / 2400W : 50Hz ± 0.2%
Supermax I 5KVA to 30KVA : 50Hz ± 0.5%
Output Waveform on UPS Mode
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : Pure Sine Wave
NM36MX1KK11 1KVA/800W : Pure Sine Wave
NM72MX2KK11 2KVA / 1600W : Pure Sine Wave
NM72MX3KK11 3KVA / 2400W : Pure Sine Wave
Supermax I 5KVA to 30KVA : Pure Sine Wave
Input Frequency
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : 45~55 Hz
NM36MX1KK11 1KVA/800W : 46~54 ± 0.5 Hz
NM72MX2KK11 2KVA / 1600W : 46~54 ± 0.5 Hz
NM72MX3KK11 3KVA / 2400W : 46~54 ± 0.5 Hz
Supermax I 5KVA to 30KVA : 45~55 Hz
Input Phase
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : Three Phase Three Wire (compatible for phase reversal)
NM36MX1KK11 1KVA/800W : 1 Phase
NM72MX2KK11 2KVA / 1600W : 1 Phase
NM72MX3KK11 3KVA / 2400W : 1 Phase
Supermax I 5KVA to 30KVA : Single phase upto 10KVA and Three Phase from 5 to 30KVA
Input Power Factor
Supermax Series - II (3 Phase in - 3 Phase out) 5KVA to 30KVA : -
NM36MX1KK11 1KVA/800W : ≥ 0.95
NM72MX2KK11 2KVA / 1600W : ≥ 0.95
NM72MX3KK11 3KVA / 2400W : ≥ 0.95
Supermax I 5KVA to 30KVA : -