Sukam Torque Series 850 VA UPS & Inverter Torque 850VA/12V A Home UPS that packs a powerful punch Traditionally, you've used a UPS to run your computer, printer, modem, router and other IT equipments, and a separate inverter for your lights, fans and other home appliances. Now, you only need one mighty machine Su-Kam's Torque Digital Home UPS systems. Powerful and sensitive at the same time, Torque will run all your IT equipment and your electrical appliances single handedly, smoothly, without a break.
If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide
Out of Stock
Capacity | 850 VA |
Series # | Torque Series |
Available on Conzumr Since | April 2017 |
4827.00 6990.00 2 | |
SnapDeal | ₹ 4827 SELL INR 4827.00 31% off |
Sukam | ₹ 6990 SELL INR 6990.00 |
Refreshed 4 years ago |
![]() | Torque 650VA/12V | 650 VA | ₹ 6400.00 |
![]() | Torque 2000VA/12V | 2000 VA | ₹ 7013.00 |
![]() | Torque 1000VA/12V | 1000 VA | ₹ 6173.00 |
![]() | Torque 2500VA/12V | 2500 VA | ₹ 26990.00 |
Technology | Micro Controller Based PWM Technology using MOSFETs. |
UPS Overload / UPS Short Circuit | Above 110% |
Charger Current | 13+_2.0 AMP |
Shot Circuit Protection | >250% load(few msec) |
Capacity | 850 VA |
Capacity Battery | 12 V |
Battery | Hups |
Efficiency (on battery mode) | >88% |
Low Battery Cutout | 10.5V+_0.2V |
Recommended Battery | 100-200 Ah |
Max. Battery Boost Level | 14.4V ± 0.2V |
Max. Battery Float Level | 13.6V ± 0.2V |
Battery Recharge Time | FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V |
Output Voltage on Mains Mode | 200V-230V ± 25V |
Output frequency on UPS Mode | 50.0 Hz +_ 0.1 Hz |
Input Frequency | 45~55 Hz |
Main AC Low Cut | 185+_10V |
Main AC Low Cut Recovery | 190+_10V |
Main AC High Cut | 265+_10V |
Main AC High Cut Recovery | 260+_10V |
Voltage Range NW UPS Mode | 185V-265V+_10V |
Voltage Range NW UPS Mode - Narrow-Wide range is the range of input voltage for which power inverter will work on line mode (external power) and then switch to backup mode. For example, you have got a power inverter that has got ‘narrow range’ of 170 V to 250 V, it won’t switch over to batteries backup if voltage is higher than 170 V and lower than 250 V. On the other hands, if ‘wide range’ is selected which is supposedly designed for 110 V to 260 V, the power inverter will not switch to backup mode as long as external power is available and voltage is higher than 110 V and lower than 260 V. |
Main AC High Cut | 285 ± 10V |
Main AC High Cut Recovery | 275 ± 10V |
Main AC Low Cut | 105 ± 10V |
Main AC Low Cut Recovery | 120 ± 10V |
Voltage Range WW UPS Mode | 105-285 ±10 V |
Weight | 9 kg |
Width | 301 mm |
Length | 302 mm |
Height | 128 mm |