Capacity | 850 VA |
Series # | Shiny Series |
Warranty(Months) | 7 |
Available on Conzumr Since | September 2015 |
4913.00 7490.00 6 | |
SnapDeal | ₹ 4913 SELL INR 4913.00 34% off |
pepperfry | ₹ 5699 SELL INR 5699.00 24% off |
Home Shop 18 | ₹ 6367 SELL INR 6367.00 15% off |
Naaptol | ₹ 7490 SELL INR 7490.00 |
Sukam | ₹ 7490 SELL INR 7490.00 |
Refreshed 2 hours ago |
Technology | Micro Controller Based PWM Technology using MOSFETs. |
UPS Overload / UPS Short Circuit | Above 100% |
Charger Current | 13+_2.0 AMP |
Shot Circuit Protection | >300% load(few msec) |
Capacity | 850 VA |
Capacity Battery | 12 V |
Battery | Hups |
Efficiency (on battery mode) | >88% |
Low Battery Cutout | 10.5V+_0.2V |
Recommended Battery | 100-200 Ah |
Max. Battery Boost Level | 13.9V ± 0.2V |
Max. Battery Float Level | 13.7V ± 0.2V |
Battery Recharge Time | FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V |
Output Voltage on Mains Mode | 180V -245 V |
Output frequency on UPS Mode | 50.0 Hz +_ 0.1 Hz |
Input Frequency | 45~55 Hz |
Main AC Low Cut | 185+_10V |
Main AC Low Cut Recovery | 190+_10V |
Main AC High Cut | 265+_10V |
Main AC High Cut Recovery | 260+_10V |
Voltage Range NW UPS Mode | 185V-265V+_10V |
Voltage Range NW UPS Mode - Narrow-Wide range is the range of input voltage for which power inverter will work on line mode (external power) and then switch to backup mode. For example, you have got a power inverter that has got ‘narrow range’ of 170 V to 250 V, it won’t switch over to batteries backup if voltage is higher than 170 V and lower than 250 V. On the other hands, if ‘wide range’ is selected which is supposedly designed for 110 V to 260 V, the power inverter will not switch to backup mode as long as external power is available and voltage is higher than 110 V and lower than 260 V. |
Main AC High Cut | 285 ± 10V |
Main AC High Cut Recovery | 275 ± 10V |
Main AC Low Cut | 105 ± 10V |
Main AC Low Cut Recovery | 120 ± 10V |
Voltage Range WW UPS Mode | 105-285 ±10 V |
Weight | 9.75 kg |
Width | 280 mm |
Length | 276 mm |
Height | 124 mm |