Sukam 1500 VA UPS & Inverter Shiny 1500 VA (Shiny Sine Wave HUPS) Handle High Current, Advanced Fuzzy Logic Control Technology, The two-way slider Selection Switch, Easy Switch-over..
In case of overload, Su-Kam's System Overload Alarm resets the Home UPS automatically.
If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide
Capacity | 1500 VA |
Series # | Shiny |
Warranty(Months) | 7 |
Available on Conzumr Since | September 2015 |
7000.00 8682.00 6 | |
Amazon.in | |
SnapDeal | ₹ 7471 SELL INR 7471.00 25% off |
Home Shop 18 | ₹ 8492 SELL INR 8492.00 15% off |
pepperfry | ₹ 9649 SELL INR 9649.00 3% off |
Sukam | ₹ 9990 SELL INR 9990.00 |
Paytm Mall | ₹ 8682 OUTOFSTOCK INR 8682.00 13% off |
Refreshed 2 days ago |
Technology | Micro Controller Based PWM Technology using MOSFETs. |
UPS Overload / UPS Short Circuit | Above 100% |
Charger Current | 13+_2.0 AMP |
Shot Circuit Protection | >300% load(few msec) |
Capacity | 1500 VA |
Capacity Battery | 24 V |
Battery | Hups |
Efficiency (on battery mode) | >88% |
Low Battery Cutout | 10.5V+_0.2V |
Recommended Battery | 100-200 Ah |
Max. Battery Boost Level | 14.4V ± 0.2V |
Max. Battery Float Level | 13.7V ± 0.2V |
Battery Recharge Time | FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V |
Output Voltage on Mains Mode | 180V -245 V |
Output frequency on UPS Mode | 50.0 Hz +_ 0.1 Hz |
Input Frequency | 45~55 Hz |
Main AC Low Cut | 185+_10V |
Main AC Low Cut Recovery | 190+_10V |
Main AC High Cut | 265+_10V |
Main AC High Cut Recovery | 260+_10V |
Voltage Range NW UPS Mode | 185V-265V+_10V |
Voltage Range NW UPS Mode - Narrow-Wide range is the range of input voltage for which power inverter will work on line mode (external power) and then switch to backup mode. For example, you have got a power inverter that has got ‘narrow range’ of 170 V to 250 V, it won’t switch over to batteries backup if voltage is higher than 170 V and lower than 250 V. On the other hands, if ‘wide range’ is selected which is supposedly designed for 110 V to 260 V, the power inverter will not switch to backup mode as long as external power is available and voltage is higher than 110 V and lower than 260 V. |
Main AC High Cut | 285 ± 10V |
Main AC High Cut Recovery | 275 ± 10V |
Main AC Low Cut | 105 ± 10V |
Main AC Low Cut Recovery | 120 ± 10V |
Voltage Range WW UPS Mode | 105-285 ±10 V |
Weight | 16.6 kg |
Width | 400 mm |
Length | 310 mm |
Height | 168 mm |