Sukam Sukam FALCON 800 VA/12 V UPS & Inverter
Falcon Sine Wave HUPS Automatic overload regulation, SMD Technology (Surface Mount Device Technology), UPS mode/Wide UPS mode
Click to Enlarge image(s)

  • Automatic overload regulation: In case of overload, the Falcon Sine Wave UPS resets itself automatically to turn on again. The system will retry 8 times to run the existing load, giving the user repeated alarms and enough time to reduce the load without having to shut down the system.
  • Highly energy efficient: The Falcon Sine Wave UPS is furnished with an SMPS-based charger, which has the highest power factor. This minimizes the amount of AC power required to charge the batteries, thereby reducing your power consumption considerably. It also provides ripple free DC supply to batteries, thus enhancing the battery life.
  • SMD Technology (Surface Mount Device Technology): The PCB card is based on Surface Mount Device Technology that reduces human error while manufacturing. Systems based on this SMD technology are more efficient than other conventional systems.
  • UPS mode/Wide UPS mode: The two-way selection switch gives you the option to select the system mode. You can select UPS mode for sensitive appliances like TVs, computers, scanners or Wide UPS mode for tube lights, fans, room coolers and refrigerators.

If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide

Check best selling models @
Highlights
Capacity 800 VA
Series # Falcon Series
Available on Conzumr Since February 2016
Buy Now FALCON 800 VA/12 V
Home Shop 18 ₹ 6741 10% off
Sukam ₹ 7490
Refreshed 1 month ago

General Specification
Technology Micro Controller Based PWM Technology using MOSFETs.
UPS Overload / UPS Short Circuit Above 110%
Charger Current 13+_2.0 AMP
Shot Circuit Protection >250% load(few msec)
Capacity 800 VA
Capacity Battery 12 V
Battery Features
Battery Hups
Efficiency (on battery mode) >88%
Low Battery Cutout 10.5V+_0.2V
Recommended Battery 100-200 Ah
Max. Battery Boost Level 14.4V ± 0.2V
Max. Battery Float Level 13.7V ± 0.2V
Battery Recharge Time FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V
Input & Output
Output Voltage on Mains Mode 200V-220V ± 25V
Output frequency on UPS Mode 50.0 Hz +_ 0.1 Hz
Input Frequency 45~55 Hz
Voltage Range NW UPS Mode
Main AC Low Cut 185+_10V
Main AC Low Cut Recovery 190+_10V
Main AC High Cut 265+_10V
Main AC High Cut Recovery 260+_10V
Voltage Range NW UPS Mode 185V-265V+_10V

Voltage Range NW UPS Mode - Narrow-Wide range is the range of input voltage for which power inverter will work on line mode (external power) and then switch to backup mode. For example, you have got a power inverter that has got ‘narrow range’ of 170 V to 250 V, it won’t switch over to batteries backup if voltage is higher than 170 V and lower than 250 V. On the other hands, if ‘wide range’ is selected which is supposedly designed for 110 V to 260 V, the power inverter will not switch to backup mode as long as external power is available and voltage is higher than 110 V and lower than 260 V.

Voltage Range WW UPS Mode
Main AC High Cut 285 ± 10V
Main AC High Cut Recovery 275 ± 10V
Main AC Low Cut 105 ± 10V
Main AC Low Cut Recovery 120 ± 10V
Voltage Range WW UPS Mode 105-285 ±10 V
Dimensions
Weight 9.9 kg
Width 280 mm
Length 275 mm
Height 124 mm