Sukam Falcon Series 600 VA UPS & Inverter FALCON 600 VA/12 V (Falcon Sine Wave HUPS) Reduced Power Consumption, Fuzzy Logic Charging Technique, User-friendly graphical display with audible alerts, Automatic overload regulation
If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide
Capacity | 600 VA |
Series # | Falcon Series |
Available on Conzumr Since | February 2016 |
6490.00 8000.00 2 | |
Sukam | ₹ 6490 SELL INR 6490.00 |
Amazon.in | |
Refreshed 2 years ago |
Technology | Micro Controller Based PWM Technology using MOSFETs. |
UPS Overload / UPS Short Circuit | Above 110% |
Charger Current | 13 ± 2.0 AMP |
Shot Circuit Protection | >250% load(few msec) |
Capacity | 600 VA |
Capacity Battery | 12 V |
Battery | Hups |
Efficiency (on battery mode) | >88% |
Low Battery Cutout | 10.5V ± 0.2V |
Recommended Battery | 100 - 200 Ah |
Max. Battery Boost Level | 14.4V ± 0.2V |
Max. Battery Float Level | 13.7V ± 0.2V |
Battery Recharge Time | FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V |
Instant Switch Over | Yes |
In case of power failure, the process of switching over the battery mode is of few milliseconds hence the power supplied to the connected appliances, like computer is not interrupted, as a result of which the system does not reboot. | |
Fuzzy Logic Charging Technique | Yes |
This is unique technology that protects the battery, reduces frequency of water topping and increases battery life by sensing the requirement of charging required by the battery. |
Output Voltage on Mains Mode | 200V-220V ± 25V |
Output frequency on UPS Mode | 50.0 Hz ± 0.1 Hz |
Input Frequency | 45~55 Hz |
Main AC Low Cut | 185 ± 10V |
Main AC Low Cut Recovery | 190 ± 10V |
Main AC High Cut | 265 ± 10V |
Main AC High Cut Recovery | 260 ± 10V |
Voltage Range NW UPS Mode | 185V-265V ± 10V |
Voltage Range NW UPS Mode - Narrow-Wide range is the range of input voltage for which power inverter will work on line mode (external power) and then switch to backup mode. For example, you have got a power inverter that has got ‘narrow range’ of 170 V to 250 V, it won’t switch over to batteries backup if voltage is higher than 170 V and lower than 250 V. On the other hands, if ‘wide range’ is selected which is supposedly designed for 110 V to 260 V, the power inverter will not switch to backup mode as long as external power is available and voltage is higher than 110 V and lower than 260 V. |
Main AC High Cut | 285 ± 10V |
Main AC High Cut Recovery | 275 ± 10V |
Main AC Low Cut | 105 ± 10V |
Main AC Low Cut Recovery | 120 ± 10V |
Voltage Range WW UPS Mode | 105-285 ±10 V |
Weight | 8.7 kg |
Width | 280 mm |
Length | 275 mm |
Height | 124 mm |