Sukam Sukam 650VA/12V UPS & Inverter
A popular product with a decade long legacy, CHIC has been specially created for those homes where there are small children as it is completely shockproof. Unlike other Home UPSs, it has a PCABS plastic body which makes it extremely safe to place inside the house without fear of small child touching it. Equipped with tough exterior, chic is able to with stand high temperature. Breaking away from traditional style, the R&D team at Su-Kam has given the CHIC Digital HUPS a very futuristic, smart look with bright color scheme, making it a lifestyle product that can only add to your home interiors.
Click to Enlarge image(s)

  • Soft start capability for starting heavy loads
  • Fire resistant and shock proof body.
  • High-end Micro Controller based design.
  • Matching battery trolley to add to your home interior.
  • User selectable heavy duty charger option that charges the battery up to 50% faster as compared to other branded models.
  • Multifunction Graphical LED display.
  • 5 LEDs display following states - operation mode, state of charge, fault message.

If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide

Check best selling models @
Highlights
Capacity 650 VA
Series # CHIC SERIES
Available on Conzumr Since November 2014
Buy Now 650VA/12V
Sukam ₹ 1800
Refreshed 3 years ago

General Specification
Technology Micro Controller Based PWM Technology using MOSFETs.
UPS Overload / UPS Short Circuit Above 110%
Charger Current 13+_2.0 AMP
Shot Circuit Protection >250% load(few msec)
Capacity 650 VA
Capacity Battery 12 V
Battery Features
Battery Hups
Efficiency (on battery mode) >88%
Low Battery Cutout 10.5V+_0.2V
Recommended Battery 100-200 Ah
Max. Battery Boost Level 13.9V ± 0.2V
Max. Battery Float Level 13.6V ± 0.2V
Battery Recharge Time FLC basedSCR charging with soft start over full range of mains 140V to 285V +_10V
Input & Output
Output Voltage on Mains Mode 200V-230V ± 25V
Output frequency on UPS Mode 50.0 Hz +_ 0.1 Hz
Input Frequency 45~55 Hz
Voltage Range NW UPS Mode
Main AC Low Cut 185+_10V
Main AC Low Cut Recovery 190+_10V
Main AC High Cut 265+_10V
Main AC High Cut Recovery 260+_10V
Voltage Range NW UPS Mode 185V-265V+_10V

Voltage Range NW UPS Mode - Narrow-Wide range is the range of input voltage for which power inverter will work on line mode (external power) and then switch to backup mode. For example, you have got a power inverter that has got ‘narrow range’ of 170 V to 250 V, it won’t switch over to batteries backup if voltage is higher than 170 V and lower than 250 V. On the other hands, if ‘wide range’ is selected which is supposedly designed for 110 V to 260 V, the power inverter will not switch to backup mode as long as external power is available and voltage is higher than 110 V and lower than 260 V.

Voltage Range WW UPS Mode
Main AC High Cut 285 ± 10V
Main AC High Cut Recovery 275 ± 10V
Main AC Low Cut 105 ± 10V
Main AC Low Cut Recovery 120 ± 10V
Voltage Range WW UPS Mode 105-285 ±10 V
Dimensions
Weight 8 kg
Width 137 mm
Length 308 mm