APC APC SUA1500I-IN UPS & Inverter
Predictive failure notification, adjustable voltage-transfer points, USB & Serial connectivity
Click to Enlarge image(s)

  • Power conditioning
  • Adjustable voltage sensitivity
  • BIS certified
  • Front-access servicing
  • Disconnected battery notification
  • LED status indicators
  • Audible alarms
  • Temperature-compensated battery charging
  • Automatic restart of loads after UPS shutdown
  • Periodic automatic battery self-test

If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide

Check best selling models @
Highlights
Capacity 1500 VA
Series # Back-up UPS Pro
Available on Conzumr Since March 2017
Buy Now SUA1500I-IN
APC ₹ 27000
Amazon.in
Refreshed 3 weeks ago

General Specification
Appliance Type UPS
Surge Rating 480 Joules
Total Harmonic Distortion (Resistive Load) Less than 5%
LED Display Red LED status display with On Line : On Battery : Replace Battery and Overload indicators
Environment Operating Temperature 0 - 40 °C
Environment Rel. Humidity 0 - 95 %
Audible Noise level 45.0 dBA
Communication Interface DB-9 RS-232 , SmartSlot , USB
Capacity 1500 VA
Operating Elevation 0-3000 meters
Storage Temperature -15 - 45 °C
Storage Relative Humidity 0 - 95%
Storage Elevation 0-15000 meters
Online Thermal Dissipation 135 btu/hr
Battery Features
Expected Battery Life In Years 3 to 5 years
Battery Volt-Amp-Hour Capacity 408
Battery Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Battery Recharge Time 3 hours
Alarm Battery Low Distinctive low battery alarm
Design
Waveform Type Sine wave

Pure Sine Wave is the purest and is 100% clean, regulated, and completely stable and distortion free power output, which is absolutely safe for running complex appliances without humming & irritating sound.

Output
Topology Line Interactive

The type of operation system of the UPS is known as topology.

Input & Output
Input Voltage 230V
Output Voltage on Mains Mode Configurable for 220, 230 or 240 nominal output voltage
Output Voltage on UPS Mode 230V
Output frequency on UPS Mode 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominal
Input Frequency 50 Hz +/- 3 Hz Hz
Output connection (8) IEC 320 C13 (Battery Backup) (2) IEC Jumpers (Battery Backup)
Voltage Range NW UPS Mode
Main AC Low Cut 160 V
Main AC High Cut 286 V
Voltage Range WW UPS Mode
Main AC High Cut 151 V
Main AC Low Cut 302 V
Dimensions
Weight 24 kg
Width 170 mm
Length 439 mm