APC Back-up UPS Pro 1000 VA UPS & Inverter SRC1KI-IN Automatic internal bypass, automatic self-test, Generator compatibility
The unique Automatic internal bypass feature gives utility power supply to the connected loads in the event of a UPS power overload or fault. Sine wave output eliminates humming and heat generated when powering tubelights and fans. Microprocessor controlled, 3-stage regulated intelligent battery charging ensures the fastest recharge times without decreasing battery life. Green mode is an operating mode, that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide
Capacity | 1000 VA |
Series # | Back-up UPS Pro |
Warranty(Months) | 24 |
Warranty Terms | 2 years repair or replace standard warranty |
Available on Conzumr Since | March 2017 |
16000.00 25056.00 3 | |
Amazon.in | |
APC | ₹ 32000 SELL INR 32000.00 |
FlipKart | ₹ 25056 OUTOFSTOCK INR 25056.00 22% off |
Refreshed 3 months ago |
![]() | BR1000G-IN | 1000 VA | ₹ 8775.00 |
![]() | SUA1000UXI | 1000 VA | ₹ 16800.00 |
![]() | SURTD5000XLI-CC | 5000 VA | ₹ 110000.00 |
![]() | BR1500G-IN | 1500 VA | ₹ 14100.00 |
![]() | SUA1000I-IN | 1000 VA | ₹ 24500.00 |
![]() | SUA750I-IN | 750 VA | ₹ 20948.00 |
![]() | SUA1500I-IN | 1500 VA | ₹ 27000.00 |
Appliance Type | UPS |
Efficiency | 90.0 % |
Total Harmonic Distortion (Resistive Load) | Less than 2% |
LED Display Red | LED status display with On Line : On Battery : Replace Battery and Overload indicators |
Environment Operating Temperature | 0 - 40 °C |
Environment Rel. Humidity | 0 - 95 % |
Communication Interface | DB-9 RS-232 , SmartSlot |
Crest Factor | 3 : 1 |
Capacity | 1000 VA |
Operating Elevation | 0-900meters |
Storage Temperature | -20 - 45 °C |
Storage Relative Humidity | 0 - 95% |
Storage Elevation | 0-4500meters |
Battery Volt-Amp-Hour Capacity | 324 |
Battery | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
Efficiency (on battery mode) | 90.0 % |
Battery Recharge Time | 6hours |
Alarm Battery Low | Distinctive low battery alarm |
Topology | Double Conversion Online |
The type of operation system of the UPS is known as topology. |
Input Voltage | 230V |
Output Voltage on Mains Mode | Configurable for 220 or 240 nominal output voltage |
Output Voltage on UPS Mode | 230V |
Output frequency on UPS Mode | 50/60Hz +/- 3 Hz |
Input Frequency | 40 - 70 Hz Hz |
Output connection | (4) India 3-pin 6A (Battery Backup) |
Weight | 13.5 kg |
Width | 145 mm |
Length | 400 mm |
Height | 220 mm |