APC Back-up UPS 600 VA UPS & Inverter BX600CI-IN Automatic self-test, Automatic Voltage Regulation (AVR), Battery charging indicator, Boost Automatic Voltage Regulation (AVR), Cold-start capable, Fast battery charging capability
The battery failure notification function, provides early-warning fault analysis on batteries enabling timely preventive maintenance. With the easy-to-read LED status display, which gives visual indicators, you can quickly understand unit and power status. The battery saver feature, extends battery life by preventing unnecessary discharges while the UPS is on battery.
If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide
Capacity | 600 VA |
Series # | Back-up UPS |
Warranty(Months) | 24 |
Warranty Terms | 2 years repair or replace standard warranty |
Available on Conzumr Since | February 2017 |
2390.00 4350.00 4 | |
Rediff | ₹ 2390 SELL INR 2390.00 45% off |
Amazon.in | |
SnapDeal | ₹ 4000 SELL INR 4000.00 8% off |
APC | ₹ 4350 SELL INR 4350.00 |
Refreshed 1 week ago |
![]() | BE700Y-IND | 700 VA | ₹ 5220.00 |
![]() | BX1100C-IN | 1100 VA | ₹ 5470.00 |
![]() | BE800-IND | 800 VA | ₹ 5643.00 |
![]() | BR1100CI-IN | 1100 VA | ₹ 6928.00 |
Appliance Type | UPS |
UPS Transfer Time | 10 ms |
Switching from Mains to UPS and from UPS to Mains | Yes |
Surge Rating | 160 Joules |
Overload Handling Capability | 290 VAC, typical |
Environment Operating Temperature | 0 - 40 °C |
Environment Rel. Humidity | 0 - 95 % |
Capacity | 600 VA |
Operating Elevation | 0-3000 meters |
Storage Temperature | -15 - 45 °C °C |
Storage Relative Humidity | 0 - 95 % |
Storage Elevation | 0-15000 meters |
Battery Volt-Amp-Hour Capacity | 60 |
Battery | VRLA |
AVR | Yes |
Battery Recharge Time | 5 to 6 hours typical for 90% charging for a fully discharged battery with 50% load |
Alarm Battery Low | Distinctive low battery alarm |
Alarm Green | Yes |
Compatible battery types | RBC2 |
Waveform Type | Stepped approximation to a sinewave |
Pure Sine Wave is the purest and is 100% clean, regulated, and completely stable and distortion free power output, which is absolutely safe for running complex appliances without humming & irritating sound. |
Topology | Line Interactive |
The type of operation system of the UPS is known as topology. |
Input Voltage | 230V |
Output Voltage on UPS Mode | 230V |
Output frequency on UPS Mode | 47 - 63 Hz |
Input Frequency | 47 - 63 Hz Hz |
Output connection | (3) India 3-pin 6A (Battery Backup) |
Input connections - To mains | India 3-pin 6A |
Main AC High Cut | 145V |
Main AC Low Cut | 290V |
Weight | 5 kg |
Width | 100 mm |
Length | 283 mm |
Height | 142 mm |