APC APC BX1100C-IN UPS & Inverter
Audible alarms, Automatic Voltage Regulation (AVR), BIS Certified, Fast battery charging capability
Click to Enlarge image(s)

On Mains to On Battery Transfer - The Back-UPS will switch to battery power if the utility input voltage level does not meet the under-voltage or over-voltage threshold, or if the utility input is experiencing voltage fluctuations, or if the input frequency is out of range.

No Load Shutdown - The no load shutdown feature works when the Battery Saver mode is enabled and the Back-UPS is in the On Battery mode. The Back-UPS will shutdown if the connected load draws less than 30 W of power for more than 5 minutes. Disable Battery Saver mode if only low power consuming equipment like ADSL-modem or wi-fi router is connected to the Back-UPS.

  • Automatic self-test
  • Battery charging indicator
  • Cold-start capable
  • Generator compatibility
  • LED Indicators
  • Boost Automatic Voltage Regulation (AVR)

If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide

Check best selling models @
Highlights
Capacity 1100 VA
Series # Back-up UPS
Warranty(Months) 24
Warranty Terms 2 years repair or replace standard warranty
Available on Conzumr Since February 2017

General Specification
Appliance Type UPS
Browns out Mains Voltage 145 VAC typical
UPS Transfer Time 10ms typical : 12ms maximum
Efficiency 72.0 %
Switching from Mains to UPS and from UPS to Mains Yes
Surge Rating 255 Joules
Overload Handling Capability 290 VAC
Environment Operating Temperature 0 - 40 °C
Environment Rel. Humidity 0 - 95 %
Capacity 1100 VA
Operating Elevation 0-3000 meters
Storage Temperature -15 - 45 °C °C
Storage Relative Humidity 0 - 95 %
Storage Elevation 0-15000meters
Battery Features
Battery Volt-Amp-Hour Capacity 173
Battery Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Efficiency (on battery mode) 72.0 %
AVR Yes
Battery Recharge Time 4 to 6 hours typical
Alarm Battery Low Distinctive low battery alarm
Alarm Green Yes
Design
Color Black
Waveform Type Stepped approximation to a sinewave

Pure Sine Wave is the purest and is 100% clean, regulated, and completely stable and distortion free power output, which is absolutely safe for running complex appliances without humming & irritating sound.

Output
Topology Line Interactive

The type of operation system of the UPS is known as topology.

Input & Output
Input Voltage 230V
Output Voltage on UPS Mode 230V
Output frequency on UPS Mode 50 Hz
Input Frequency 45 - 65 Hz (auto sensing) Hz
Input connections - To mains 3-pin 6A
Voltage Range WW UPS Mode
Main AC High Cut 145V
Main AC Low Cut 290V
Dimensions
Weight 8.98 kg
Width 132 mm
Length 259 mm
Height 282 mm