APC APC BR1100CI-IN UPS & Inverter
LED status indicators, Replace Battery LED, Resettable circuit breakers, audible alarms, RoHS compliant
Click to Enlarge image(s)

  • The Dataline surge protection feature provides protection of connected equipment from power surges on the data lines.
  • Battery replacement without tools, enables fast battery replacement, lowering Mean Time to Repair (MTTR).
  • Resettable circuit breakers, enables a quick recovery from overload events.
  • BIS certification, ensures that the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Periodic automatic battery self-test ensures early detection of a battery that needs to be replaced.

If you need futher guidance regarding various things to consider while purchasing UPS & Inverter, please read our Conzumr Guide

Check best selling models @
Highlights
Capacity 1100 VA
Series # Back-up UPS
Warranty(Months) 24
Warranty Terms 2 years repair or replace standard warranty
Available on Conzumr Since February 2017

General Specification
Appliance Type UPS
Browns out Mains Voltage 155 Vac Typical
UPS Transfer Time 6 ms Typical
Surge Rating 441Joules
Overload Handling Capability 290 VAC, typical
Environment Operating Temperature 0 - 40 °C
Environment Rel. Humidity 0 - 95 %
Data Line Protection Analog phone line for phone/fax/modem/DSL (RJ-11 connector)
Capacity 1100 VA
Operating Elevation 0-3000 meters
Storage Temperature -5 - 45 °C
Storage Relative Humidity 0 - 95 %
Storage Elevation 0-15000meters
Battery Features
Expected Battery Life In Years 2 to 4 years
Battery Volt-Amp-Hour Capacity 180
Battery Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
AVR Yes
Battery Recharge Time 6 to 10 hours
Alarm Battery Low Distinctive low battery alarm
Alarm Green Yes
Compatible battery types APCRBC113
Design
Color Charcoal
Output
Topology Line Interactive

The type of operation system of the UPS is known as topology.

Input & Output
Input Voltage 230V
Output Voltage on UPS Mode 230V
Input Frequency 47 - 63 Hz Hz
Output connection 2) India 2/3-pin 6A (selector_surgetitle) (3) India 2/3-pin 6A (Battery Backup)
Input connections - To mains Indian/South African BS 546A
Voltage Range NW UPS Mode
Main AC Low Cut 175V
Main AC High Cut 295V
Voltage Range WW UPS Mode
Main AC High Cut 160V
Main AC Low Cut 286V
Dimensions
Weight 11 kg
Width 132 mm
Length 356 mm
Height 222 mm