Write a review / Comment on disqus
List of 1 Ton 5 Star Voltas Acs in 2017

You can see list of our Compare 1 Ton 5 star Voltas ACs below, perform Side-by-Side comparison. If you need further help, do have a look at Conzumr Guides and Tips. Alternatively you can view all Air Conditioner to choose your own favourites.


An air conditioner is basically a fridge without the insulated box. A fridge only cools the space inside it, but an air conditioner cools the room outside.

There are many features to look for while buying an ac like type of ac inverter or non-inverter, hot cold feature, tonnage, energy efficient class, various functions, air swing direction etc


Voltas 1.0T 125 LYd

100% Copper condenser, Anti dust filter, 5 star energy saver ratings, Cross flow, 1036 watt power consumption

  • LED display
  • Self diagnosis
  • Auto restart
  • Sleep mode
  • LCD remote
  • Timer
  • IR control with Smartphone

Voltas 1.0 T 125 CYu

High EER Rotary, air Flow Volume (Indoor): 850 CMH, Air Vent: Cross Flow

Voltas 1.0 T 125 CYe

Air vent is cross flow, Filters are anti dust and fin is hydrophylic aluminum golden, Noise level 48 db

Voltas 1.0 T 125 EY(S)

Voltas 125 EYS 1 Ton 5 Star (2017) Split AC

Rated current: Cooling 4.5 Amps, Rated EER W/W 3.51, Power supply 230 / 50 / 1 phase

Voltas 1.0 Ton 125 CYa

Anti Dust, Catechin Filter, Acaro Bacterium(Red), Auto Restart, Dual Temp Display, Fungusproof, Cross Flow Air Vent


Side by Side comparison

Alt Model #
1.0T 125 LYd : 1.0 Ton 125 LYd
1.0 T 125 CYu : 
1.0 T 125 CYe : 
1.0 T 125 EY(S) : 
1.0 Ton 125 CYa : 
Series #
1.0T 125 LYd : Luxary - 5 Star (Yd Series)
1.0 T 125 CYu : Classic - 5 Star(Yu Series)
1.0 T 125 CYe : Classic - (Ye Series)
1.0 T 125 EY(S) : Executive - (Y-S Series)
1.0 Ton 125 CYa : Classic - 5 Star (Ya Series)
1.0T 125 LYd
1.0 T 125 CYu
1.0 T 125 CYe
1.0 T 125 EY(S)
1.0 Ton 125 CYa
Highlights
AC Type
1.0T 125 LYd : Split
1.0 T 125 CYu : Split
1.0 T 125 CYe : Split
1.0 T 125 EY(S) : Split
1.0 Ton 125 CYa : Split
1.0T 125 LYd : 1 TR
1.0 T 125 CYu : 1 TR
1.0 T 125 CYe : 1 TR
1.0 T 125 EY(S) : 1 TR
1.0 Ton 125 CYa : 1 TR
A ton is a measurement of heat transfer. One ton is equal to 12,000 BTU's(British thermal unit) per hour. It is derived from the amount of energy that it takes to melt one ton of ice in a twenty four hour period.
1.0T 125 LYd : Non-Inverter AC
1.0 T 125 CYu : Non-Inverter AC
1.0 T 125 CYe : Non-Inverter AC
1.0 T 125 EY(S) : Non-Inverter AC
1.0 Ton 125 CYa : Non-Inverter AC
Non-Inverter AC: Non inverter or Fixed speed air conditioning deliver a fixed amount of power via a fixed speed. This means the compressor has to stop and start to maintain the desired room temperature. This means that it operates either at full or minimum speed. Switching on this type of unit will start to run on full load thus consuming more power.
1.0T 125 LYd : 3.55
1.0 T 125 CYu : 3.6
1.0 T 125 CYe : 3.6
1.0 T 125 EY(S) : 3.51
1.0 Ton 125 CYa : 3.51
Energy Efficiency cooling mode value specified by manufacturer. This is the energy efficiency calculated while using the cooling mode of the air conditioner. The higher the EER rating, the more efficient the air conditioner
1.0T 125 LYd : Cooling Only
1.0 T 125 CYu : Cooling Only
1.0 T 125 CYe : Cooling Only
1.0 T 125 EY(S) : Cooling Only
1.0 Ton 125 CYa : Cooling Only
Cooling Only: It is a great option for keeping the home cooled off during the hot summer days.
1.0T 125 LYd : 3.55
1.0 T 125 CYu : 3.55
1.0 T 125 CYe : 3.46
1.0 T 125 EY(S) : 3.47
1.0 Ton 125 CYa : 3.51
Energy Efficiency cooling mode computed value (This is the calculated EER value, considering the company specified data or info that is claimed by the manufacturer). This value shows the actual deviation of the EER (Calculated/ Computed) from the company specified value of EER.
1.0T 125 LYd : R22
1.0 T 125 CYu : R22
1.0 T 125 CYe : R22
1.0 T 125 EY(S) : R22
1.0 Ton 125 CYa : R22

It is a fluid that is used in refrigerators and air-conditioners to remove heat from the inside and throw it out in the atmosphere.

  • R290 - R-290 is a Greenest new hydrocarbon Propane refrigerant which is completely halogen free and hence seems to cause no harm to ozone layer. We have few manufacturers who are using this refrigerant and marketing their models as 7 star. The drawback of this refrigerant is that it is highly flammable and hence need extra security measures which adds to the cost of the air conditioner.
  • R-32 - R-32 efficiently conveys heat, it can reduce electricity consumption up to approximately 10 percent compared to that of air conditioners using refrigerant R-22. R32 is proposed to be used in some ACs which currently uses R410A. It is mildly flammable and has similar performance and operating conditions to R410A. It has a lower global warming potential (GWP) than the commonly used HFCs.
  • R410A - R1410 is the green gas and an environmentally friendly refrigerant which is Non-CFC. That meant in case your system ever leaks, it won't cause any harm to ozone layer. R-410 A refrigerant is better in terms of ‘global warming’, safe and more energy efficient.
  • R22 - R22 is a single hydro-chlorofluorocarbon (HCFC) compound. It has low chlorine content but causes ozone depletion. R22 wont be manufactured from year 2010. Only recycled or remaining stock of R22 can be used.
  • Energy Star Rating
    1.0T 125 LYd : 5
    1.0 T 125 CYu : 5
    1.0 T 125 CYe : 5
    1.0 T 125 EY(S) : 5
    1.0 Ton 125 CYa : 5
    Classification
    1.0T 125 LYd : High EER Rotary
    1.0 T 125 CYu : High EER Rotary
    1.0 T 125 CYe : High EER Rotary
    1.0 T 125 EY(S) : High EER Rotary
    1.0 Ton 125 CYa : High EER Rotary
    This is a superior type of a compressor and it compresses air in a confined space. These are more compact, operate quietly, built for continuous operation and typically see less maintenance. The down side is the initial costs are higher. For less than 3 ton these are good options as they don't need high duty cycle and have better energy ratings.
    1.0T 125 LYd : Dust Filter
    1.0 T 125 CYu : Anti-Bacterial Filter, Anti Fungal, Detachable & Washable Air Filter, Catechin Filter, Dust Filter, Silver Ion
    1.0 T 125 CYe : Anti-Bacterial Filter, Anti Fungal, Detachable & Washable Air Filter, Catechin Filter, Dust Filter, Silver Ion
    1.0 T 125 EY(S) : Anti Fungal, Detachable & Washable Air Filter, Catechin Filter, Dust Filter, Silver Ion, Vitamin C Filter
    1.0 Ton 125 CYa : Anti-Bacterial Filter, Anti Fungal, Detachable & Washable Air Filter, Catechin Filter, Dust Filter, Silver Ion
    Filter helps to keep the environment clean
    Anti-Bacterial Filter: The anti-bacterial filter keeps you safe and healthy as you breath in only clean, pure air. The titanium apatite photo-catalytic air purifying filter is optional
    Anti-Bacterial Filter: The anti-bacterial filter keeps you safe and healthy as you breath in only clean, pure air. The titanium apatite photo-catalytic air purifying filter is optional
    Control Type
    1.0T 125 LYd : IR control with smartphone
    1.0 T 125 CYu : -
    1.0 T 125 CYe : -
    1.0 T 125 EY(S) : -
    1.0 Ton 125 CYa : -
    1.0T 125 LYd : Hydrophylic aluminium blue fin
    1.0 T 125 CYu : -
    1.0 T 125 CYe : Hydrophylic
    1.0 T 125 EY(S) : -
    1.0 Ton 125 CYa : Hydrophylic Aluminium
    Evaporator fins are located on the evaporator and is function is to t extract heat from the air by thermal energy exchange process that occurs with the surrounding air. Air is blown across the evaporator fins where it is cooled and then sent from the air conditioner through ducts and vents and into various rooms.
    Power and Capacity
    1.0T 125 LYd : 3.68 kW
    1.0 T 125 CYu : 3.6 kW
    1.0 T 125 CYe : 3.5 kW
    1.0 T 125 EY(S) : 3.51 kW
    1.0 Ton 125 CYa : 3.55 kW
    1 kW = 3412.142 BTU/hr
    1.0T 125 LYd : 800 m3/h
    1.0 T 125 CYu : 850 m3/h
    1.0 T 125 CYe : 850 m3/h
    1.0 T 125 EY(S) : 630 m3/h
    1.0 Ton 125 CYa : 600 m3/h
    Air flow is a measurement of the amount of air per unit of time that flows through a particular device.
    Cooling Capacity (Desired)
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    Air Circulation Rate
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    Cooling Capacity
    1.0T 125 LYd : 12556.68 btu/hr
    1.0 T 125 CYu : 12283.71 btu/hr
    1.0 T 125 CYe : 11942.5 btu/hr
    1.0 T 125 EY(S) : 11976.62 btu/hr
    1.0 Ton 125 CYa : 12113.1 btu/hr
    Power (Cooling)
    1.0T 125 LYd : 1036 W
    1.0 T 125 CYu : 1013 W
    1.0 T 125 CYe : 1013 W
    1.0 T 125 EY(S) : 1011 W
    1.0 Ton 125 CYa : 1011 W
    Heating Capacity
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    Power Supply (Volt/Phase/Hz.)
    1.0T 125 LYd : 230 / 50 / 1 Phase
    1.0 T 125 CYu : 230 / 50 / 1 Phase
    1.0 T 125 CYe : 230 / 50 / 1 Phase
    1.0 T 125 EY(S) : 230 / 50 / 1 Phase
    1.0 Ton 125 CYa : 230 / 50 / 1 Phase
    Running Current -Cooling Mode
    1.0T 125 LYd : 4.6 A
    1.0 T 125 CYu : 4.5 A
    1.0 T 125 CYe : 4.5 A
    1.0 T 125 EY(S) : 4.5 A
    1.0 Ton 125 CYa : 4.5 A
    Functions
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    An auto restart facility helps to restore the original setting after a power break.
    Night Glow Buttons on Remote
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    On/Off Timer
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    The timer button on the remote automatically selects the night set mode, which prevents excessive heating/cooling of the room. The perfect temperature gives you a sound, undisturbed sleep, which keeps you healthy, fresh and ready to go the next day.
    Display
    1.0T 125 LYd : LED
    1.0 T 125 CYu : LED
    1.0 T 125 CYe : LED
    1.0 T 125 EY(S) : LED
    1.0 Ton 125 CYa : LED
    Security Lock
    1.0T 125 LYd : -
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    Turbo Mode
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    Self Diagnosis
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    LCD Remote Control
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : -
    1.0 T 125 EY(S) : -
    1.0 Ton 125 CYa : 
    Air Swing
    Auto Air Swing (Up-Down)
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    Noise Level
    Indoor - Cooling Noise
    1.0T 125 LYd : 43/38/33 dB
    1.0 T 125 CYu : 48 dB
    1.0 T 125 CYe : 48 dB
    1.0 T 125 EY(S) : 38 dB
    1.0 Ton 125 CYa : 38 dB
    Pipe Details
    1.0T 125 LYd : 3 m
    1.0 T 125 CYu : -
    1.0 T 125 CYe : -
    1.0 T 125 EY(S) : -
    1.0 Ton 125 CYa : -
    Maximum length = Maximum length allowed between indoor and outdoor unit.
    Grooved Piping
    1.0T 125 LYd : 
    1.0 T 125 CYu : 
    1.0 T 125 CYe : 
    1.0 T 125 EY(S) : 
    1.0 Ton 125 CYa : 
    100% Copper Piping
    1.0T 125 LYd : 
    1.0 T 125 CYu : -
    1.0 T 125 CYe : -
    1.0 T 125 EY(S) : -
    1.0 Ton 125 CYa : -
    Weight and Dimensions
    Outdoor unit Weight
    1.0T 125 LYd : 34 kg
    1.0 T 125 CYu : 33.5 kg
    1.0 T 125 CYe : 33.5 kg
    1.0 T 125 EY(S) : 15.5 kg
    1.0 Ton 125 CYa : 32.5 kg
    Indoor Unit Weight
    1.0T 125 LYd : 11.2 kg
    1.0 T 125 CYu : 12 kg
    1.0 T 125 CYe : 12 kg
    1.0 T 125 EY(S) : 13 kg
    1.0 Ton 125 CYa : 9.5 kg
    Indoor - Width
    1.0T 125 LYd : 950 mm
    1.0 T 125 CYu : 940 mm
    1.0 T 125 CYe : 940 mm
    1.0 T 125 EY(S) : 940 mm
    1.0 Ton 125 CYa : 845 mm
    Indoor - Height
    1.0T 125 LYd : 300 mm
    1.0 T 125 CYu : 300 mm
    1.0 T 125 CYe : 300 mm
    1.0 T 125 EY(S) : 298 mm
    1.0 Ton 125 CYa : 195 mm
    Indoor - Depth
    1.0T 125 LYd : 202 mm
    1.0 T 125 CYu : 222 mm
    1.0 T 125 CYe : 222 mm
    1.0 T 125 EY(S) : 200 mm
    1.0 Ton 125 CYa : 275 mm
    Outdoor - Width
    1.0T 125 LYd : 840 mm
    1.0 T 125 CYu : 840 mm
    1.0 T 125 CYe : 840 mm
    1.0 T 125 EY(S) : 840 mm
    1.0 Ton 125 CYa : 840 mm
    Outdoor - Height
    1.0T 125 LYd : 540 mm
    1.0 T 125 CYu : 540 mm
    1.0 T 125 CYe : 540 mm
    1.0 T 125 EY(S) : 540 mm
    1.0 Ton 125 CYa : 540 mm
    Outdoor - Depth
    1.0T 125 LYd : 300 mm
    1.0 T 125 CYu : 300 mm
    1.0 T 125 CYe : 300 mm
    1.0 T 125 EY(S) : 300 mm
    1.0 Ton 125 CYa : 300 mm


    Guides and Tips

    An air conditioner is basically a fridge without the insulated box. A fridge only cools the space inside it, but an air conditioner cools the room outside.

    There are many features to look for while buying an ac like type of ac inverter or non-inverter, hot cold feature, tonnage, energy efficient class, various functions, air swing direction etc


    Tips and Tricks to reduce your AC’s power consumption

    Air conditioners are likely one of the biggest consumers of power at your home or office. What follows below are some easy to follow tips that would reduce your power consumption while using an AC...

    continue reading

    Air Conditioner buying made painless!

    With increased affordability and soaring summer temperatures, the air conditioner, an appliance that was once considered a luxury is now a necessity within the common man’s reach. Lower prices due to technical advancements, lower maintenance costs competitive rates from a number of manufacturers have made air conditioners as affordable as ever. Let us help make your air conditioner shopping experience hassle free and pleasant. With so many options available in the market today, consider the following features in an AC before making a purchase...

    continue reading