Series #
1.0 T 125 EY(R) : Executive - (Y-R Series)
1.5 T 185 EY(R) : Executive - (Y-R Series)
1.0 T 125 EY(R)
1.5 T 185 EY(R)
Highlights
AC Type
1.0 T 125 EY(R) : Split
1.5 T 185 EY(R) : Split
1.0 T 125 EY(R) : 1 TR
1.5 T 185 EY(R) : 1.5 TR
A ton is a measurement of heat transfer. One ton is equal to 12,000 BTU's(British thermal unit) per hour. It is derived from the amount of energy that it takes to melt one ton of ice in a twenty four hour period.
1.0 T 125 EY(R) : Non-Inverter AC
1.5 T 185 EY(R) : Non-Inverter AC
Non-Inverter AC: Non inverter or Fixed speed air conditioning deliver a fixed amount of power via a fixed speed. This means the compressor has to stop and start to maintain the desired room temperature. This means that it operates either at full or minimum speed. Switching on this type of unit will start to run on full load thus consuming more power.
1.0 T 125 EY(R) : -
1.5 T 185 EY(R) : 3.51
Energy Efficiency cooling mode value specified by manufacturer. This is the energy efficiency calculated while using the cooling mode of the air conditioner. The higher the EER rating, the more efficient the air conditioner
1.0 T 125 EY(R) : Cooling Only
1.5 T 185 EY(R) : Cooling Only
Cooling Only: It is a great option for keeping the home cooled off during the hot summer days.
1.0 T 125 EY(R) : 
1.5 T 185 EY(R) : 5
Energy Efficiency cooling mode computed value (This is the calculated EER value, considering the company specified data or info that is claimed by the manufacturer). This value shows the actual deviation of the EER (Calculated/ Computed) from the company specified value of EER.
1.0 T 125 EY(R) : -
1.5 T 185 EY(R) : R22

It is a fluid that is used in refrigerators and air-conditioners to remove heat from the inside and throw it out in the atmosphere.

  • R290 - R-290 is a Greenest new hydrocarbon Propane refrigerant which is completely halogen free and hence seems to cause no harm to ozone layer. We have few manufacturers who are using this refrigerant and marketing their models as 7 star. The drawback of this refrigerant is that it is highly flammable and hence need extra security measures which adds to the cost of the air conditioner.
  • R-32 - R-32 efficiently conveys heat, it can reduce electricity consumption up to approximately 10 percent compared to that of air conditioners using refrigerant R-22. R32 is proposed to be used in some ACs which currently uses R410A. It is mildly flammable and has similar performance and operating conditions to R410A. It has a lower global warming potential (GWP) than the commonly used HFCs.
  • R410A - R1410 is the green gas and an environmentally friendly refrigerant which is Non-CFC. That meant in case your system ever leaks, it won't cause any harm to ozone layer. R-410 A refrigerant is better in terms of ‘global warming’, safe and more energy efficient.
  • R22 - R22 is a single hydro-chlorofluorocarbon (HCFC) compound. It has low chlorine content but causes ozone depletion. R22 wont be manufactured from year 2010. Only recycled or remaining stock of R22 can be used.
  • Energy Star Rating
    1.0 T 125 EY(R) : 5
    1.5 T 185 EY(R) : 5
    Warranty(Months)
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 12
    Warranty Terms
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 1 year warranty on product and 5 years warranty on compressor
    Power and Capacity
    1.0 T 125 EY(R) : -
    1.5 T 185 EY(R) : 5.05 kW
    1 kW = 3412.142 BTU/hr
    Cooling Capacity (Desired)
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    Air Circulation Rate
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    Cooling Capacity
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 17231.32 btu/hr
    Power (Cooling)
    1.0 T 125 EY(R) : 1028 W
    1.5 T 185 EY(R) : 1011 W
    Rated Capacity
    1.0 T 125 EY(R) : -
    1.5 T 185 EY(R) : 3.55 kW
    Heating Capacity
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    Power Supply (Volt/Phase/Hz.)
    1.0 T 125 EY(R) : -
    1.5 T 185 EY(R) : 220-240v/1ph/50Hz
    Running Current -Cooling Mode
    1.0 T 125 EY(R) : -
    1.5 T 185 EY(R) : 6.3 A
    Functions
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    An auto restart facility helps to restore the original setting after a power break.
    Night Glow Buttons on Remote
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    On/Off Timer
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    The timer button on the remote automatically selects the night set mode, which prevents excessive heating/cooling of the room. The perfect temperature gives you a sound, undisturbed sleep, which keeps you healthy, fresh and ready to go the next day.
    Display
    1.0 T 125 EY(R) : LED
    1.5 T 185 EY(R) : LED
    Security Lock
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    Turbo Mode
    1.0 T 125 EY(R) : -
    1.5 T 185 EY(R) : 
    Self Diagnosis
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    LCD Remote Control
    1.0 T 125 EY(R) : -
    1.5 T 185 EY(R) : 
    Air Swing
    Auto Air Swing (Up-Down)
    1.0 T 125 EY(R) : 
    1.5 T 185 EY(R) : 
    General Details
    Front Casing Colour
    1.0 T 125 EY(R) : -
    1.5 T 185 EY(R) : Red
    Noise Level
    Indoor - Cooling Noise
    1.0 T 125 EY(R) : 29 dB
    1.5 T 185 EY(R) : 29 dB
    Accessories
    Accessories
    1.0 T 125 EY(R) : -
    1.5 T 185 EY(R) : Remote Control
    Weight and Dimensions
    Outdoor unit Weight
    1.0 T 125 EY(R) : 32.5 kg
    1.5 T 185 EY(R) : 15.5 kg
    Indoor Unit Weight
    1.0 T 125 EY(R) : 9.5 kg
    1.5 T 185 EY(R) : 13 kg
    Indoor - Width
    1.0 T 125 EY(R) : 845 mm
    1.5 T 185 EY(R) : 940 mm
    Indoor - Height
    1.0 T 125 EY(R) : 196 mm
    1.5 T 185 EY(R) : 298 mm
    Indoor - Depth
    1.0 T 125 EY(R) : 275 mm
    1.5 T 185 EY(R) : 200 mm
    Outdoor - Width
    1.0 T 125 EY(R) : 845 mm
    1.5 T 185 EY(R) : 840 mm
    Outdoor - Height
    1.0 T 125 EY(R) : 300 mm
    1.5 T 185 EY(R) : 540 mm
    Outdoor - Depth
    1.0 T 125 EY(R) : 540 mm
    1.5 T 185 EY(R) : 300 mm